Solar Battery – Must Solar Battery LITHIUM IRON PHOSPHATE BATTERY – LP 16-48200
Solar Battery – Must Solar Battery LITHIUM IRON PHOSPHATE BATTERY – LP 16-48200
ELECTRICAL PERFORMANCE
Nominal Voltage |
51.2V |
Nominal Capacity |
200 Ah |
Capacity @20A |
600 min |
Energy |
10240 Wh |
Communication |
CAN2.0/RS232/RS485 |
Resistance |
<45 mΩ @ 50% SOC |
Efficiency |
>96% |
Module Parallel |
Up to 3 packs |
CHARGE PERFORMANCE
Recommended Charge Current |
20A |
Maximum Charge Current |
100A |
Recommended Charge Voltage |
57.6V |
BMS Charge Cut-Off Voltage |
<58.4 V (3.65V/Cell) |
Reconnect Voltage |
<57.6 V (3.65V/Cell) |
Balancing Voltage |
<57.6 V (3.65V/Cell) |
Maximum Batteries in Series |
16(Consult MUST) |
DISCHARGE PERFORMANCE
Maximum Continuous Discharge Current |
100 A |
Peak Discharge Current |
110 A (3s) |
BMS Discharge Cut-Off Current |
150 A (300ms) |
Balancing open voltage |
55.2V (3.45V/Cell) |
Recommended Low Voltage Disconnect |
44 V (2.75V/Cell) |
BMS Discharge Cut-Off Voltage |
>32.0V (2s) (2.0V/Cell) |
Reconnect Voltage |
>40.0 V (2.5V/Cell) |
Short Circuit Protection |
250 ~ 500 μs |
COMPLIANCE
Certifications |
CE (battery) UN38.3 (battery) UL 1642 & IEC62133 (cells) |
Shipping Classification |
UN 3480, CLASS 9 |
MECHANICAL PERFORMANCE
Dimension (L x W x H) |
580 x 420 x 230 mm 21.7 x 16.5 x 9.05’’ |
Approx. Weight |
37.2 Ibs (82 kg) |
Terminal Type |
DIN POST |
Terminal Torque |
80 ~ 100 in-Ibs (9 ~ 11 N-m) |
Case Material |
SPPC |
Enclosure Protection |
IP65 |
TEMPERATURE PERFORMANCE
Discharge Temperature |
-4 ~ 131 ºF (-20 ~ 55 ºC) |
Charge Temperature |
-4 ~ 113 ºF (0 ~ 45 ºC) |
Storage Temperature |
23 ~ 95 ºF (-5 ~ 35 ºC) |
BMS High Temperature |
149 ºF (65 ºC) |
Reconnect Temperature |
131 ºF (55 ºC) |
HEATING FOIL PERFORMANCE
Heating Temperature Range |
-4 to 41 ºF (-20 to 5 ºC) |
Heating Time |
Approximately 1 hour @ 7.5 A |
BMS Heating Foil Cut-Off |
158 ºF (70 ºC) |